GS716Tv2 and GS724Tv3 Software Administration Manual
1. Click System Management Green Ethernet Configuration.
Figure 2-8
Table 2-8. Green Ethernet Configuration Fields
Field
Auto Power Down Mode
Short Cable Mode
2. In the Auto Power Down Mode or Short Cable Mode field, select Enable or Disable to turn
the feature on or off.
3. Click Apply to send the updated configuration to the switch. Configuration changes take
effect immediately.
SNMP V1/V2
The System SNMP SNMP V1/V2 folder contains links to the following pages:
•
"Community Configuration" on page 2-17
•
"Trap Configuration" on page 2-19
•
"Trap Flags" on page 2-20
2-16
Description
When this is enabled and the port link is down, the PHY automatically
goes down for a short amount of time and then wakes up to check link
pulses. This performs auto-negotiation and saving power consumption
routines when a link partner is unavailable.
A cable test is performed when this is enabled and the port link is up at
1 Gbps: if the cable is less than 10m, PHYs are placed in low power
mode (nominal power)
v1.0, July 2009
Configuring System Information