Chapter 9: Converting Windows Installer Packages to Virtual Applications
Windows Installer Converter Reference
Error -9022: Complus Table
The following table documents this message:
Table 9-52 • Error -9022: Complus Table
Category
Type:
Message:
Cause:
Resolution:
Error -9024: FileSFPCatalog
The following table documents this message:
Table 9-53 • Error -9024: FileSFPCatalog
Category
Type:
Message:
Cause:
Resolution:
712
Description
Error
The conversion process does not support data in the MSI table 'Complus'.
You encounter this error when the Windows Installer package that you are converting
includes a Complus table. During the conversion process, the Complus table is not read.
The Complus table contains information needed to install COM+ applications. While Citrix
XenApp supports communicating with COM+ applications, it does not support installing
COM+ services. Therefore, this application cannot be deployed on Citrix XenApp.
Description
Error
The conversion process does not support data in the MSI table 'FileSFPCatalog'.
You encounter this error when the Windows Installer package that you are converting
includes a FileSFPCatalog table. During the conversion process, the FileSFPCatalog table
is not read.
The FileSFPCatalog table associates specified files with the catalog files used by system file
protection. If this file is necessary for the function of the application, you need to use
Repackager to repackage the application.