6 Remove the cooling shroud. See "Removing the Cooling Shroud" on
page 54.
7 Check the memory channels and ensure that they are populated correctly.
See "General Memory Module Installation Guidelines" on page 61.
8 Reseat the memory modules in their sockets. See "Installing Memory
Modules" on page 65.
9 Replace the cooling shroud. See "Installing the Cooling Shroud" on
page 55.
10 Close the system. See "Closing the System" on page 54.
11 Reconnect the system to its electrical outlet, and turn on the system
and attached peripherals.
12 Enter the System Setup program and check the system memory setting.
See "System Memory Settings" on page 36.
If the problem is not resolved, proceed with the next step.
13 Turn off the system and attached peripherals, and disconnect the system
from the power source.
14 Open the system. See "Opening the System" on page 53.
15 If an error message indicates a specific memory module as faulty, swap or
replace the module.
16 To troubleshoot an unspecified faulty memory module, replace the
memory module in the first DIMM socket with a module of the same type
and capacity. See "Installing Memory Modules" on page 65.
17 Close the system. See "Closing the System" on page 54.
18 Reconnect the system to its electrical outlet, and turn on the system and
attached peripherals.
19 As the system boots, observe any error message that appears and the
LED indicators on the front of the system.
20 If the memory problem is still indicated, repeat step 13 through step 19 for
each memory module installed.
If the problem persists after all memory modules have been checked,
see "Getting Help" on page 119.