Server Menu

NOTE:
Delay Time, Minimum time, and Maximum time are only shown in SETUP
screen when AC Power Recovery Delay is set to User define. The selection of
Restore on AC Power Loss setup to Power-on or Last State takes 60 seconds for
running BMC initialization after AC Power on.
Option
Status of BMC
IPMI Specification
Version
BMC Firmware Version
Set BMC LAN
Configuration
Remote Access
Configuration
Restore on AC Power
Loss (Power Off default)
Power Staggering
AC Recovery (User
Defined default)
Power On Delay
View BMC System
Event Log
Clear BMC System
Event Log
Event Logging
(Enabled default)
ECC Event Logging
(Enabled default)
PCI Error Logging
(Enabled default)
42
Using the System Setup Program
Description
Displays the status of BMC.
Displays the BMC supported IPMI version.
Displays the firmware version of BMC.
Input for Set LAN configuration command.
Configures remote access.
Restores the AC power setting. The options are Power
Off, Power On and Last State.
Selects the time of system power on after BMC initiates.
Immediate: powers on directly after BMC initiates.
Random: randomly selects time to power on.
User define: allows the user to select the time.
Displays the AC power recovery delay time.
Displays all events in the BMC Event Log.
Clears all events in BMC System Event Log.
Enables or disables BIOS to record Event Logging.
Enables or disables ECC Event Logging.
Enable or disable PCI Error Logging.