Code
Log in BMC Error Message
0082
Yes
0083
Yes
0101
Yes
0102
Yes
0120
Yes
0121
Yes
24
About Your System
Secondary Master
Drive - ATAPI
Incompatible
Secondary Slave
Drive - ATAPI
Incompatible
Warning! This
system board does
not support the
power requirements
of the installed
processor. The
processor will be run
at a reduced
frequency, which will
impact system
performance.
Error! The CPU
Core to Bus ratio or
VID configuration
has failed! Please
enter BIOS Setup
and re-config it.
Thermal Failure
detected by
PROCHOT#.
Thermal Failure
detected by
PROCHOT#.
Corrective Action
See "Troubleshooting a Hard Drive" on
page 105.
See "Troubleshooting a Hard Drive" on
page 105.
Ensure that your processors match and
conform to the type described in the
processor technical specifications
outlined in your system's Getting Started
Guide.
See "Troubleshooting Processors" on
page 108.
The message is displayed on the screen,
an error is logged to the SEL, and user
input is required to continue. The user
can take immediate corrective action or
choose to continue booting.
Ensure that the processor heat sinks are
properly installed.
See "Troubleshooting Processors" on
page 108 and "Troubleshooting System
Cooling Problems" on page 102.
Ensure that the processor heat sinks are
properly installed.
See "Troubleshooting Processors" on
page 108 and "Troubleshooting System
Cooling Problems" on page 102.