Delay Hold

The delay time is set to ignore measured values immediately after the timing input. This is
useful for avoiding bounding during device startup and the influence of machine vibration.
The delay time (the delay between timing input and start of sampling) and the sampling
period can be set.
Setting value
OFF
ON
ZX-GT User's Manual
Description
The delay time is not set. (default value)
The delay time is set.
After selecting this value, set the following items:
• Delay Time
Set the delay time.
Range: 0 to 5999 (ms)
• Sampling Time
Set the sampling time (or sampling period).
Range: 0 to 5999 (ms)
Important
Set so that the sum of the delay time and sampling time is less than
the timing input ON interval. If the next timing input for
measurement is received before the "sum of delay time and
sampling time" has elapsed, that timing input will be ignored and
will not be reflected in the sampling.
ON
Timing input
OFF
Delay time
Sampling period
Ignored
Setting Hold Functions