Default Values - Omron ZX-GT User Manual

Zx-gt series smart sensor
Hide thumbs Also See for ZX-GT:
Table of Contents

Advertisement

Default Values

The following table summarizes the default values of this Controller.
Function
Measurement cycle
Measurement mode
Averaging number
Hysteresis
Hold
Judgment output timing (timer) OFF
Special functions
Zero reset memory
Zero reset
Display reverse
ECO mode
Number of display digits
Output scaling
Baud rate
Data length
Stop bit
Parity
Header/footer selection
Binary output cycle (ms)
Binary level (%)
Edge filter
Bank switching setting
Bank
HIGH threshold
LOW threshold
142
Default Values
Default Value
Standard mode (NORM)
Interrupted beam width measurement
16
00.100
OFF
CLOSE
OFF
00.000
OFF
OFF
5 digits
Voltage
Measured value 0 mm:
Measured value 28 mm: 4 V
38400
8
1
None
CR
1
25
7
Control key operation
1
20.000
10.000
4 V
ZX-GT User's Manual