Hysteresis - Omron ZX-GT User Manual

Zx-gt series smart sensor
Hide thumbs Also See for ZX-GT:
Table of Contents

Advertisement

Hysteresis

Set the hysteresis width (difference between operation point and return point) for the
upper and lower limits of the judgments if the HIGH, PASS, or LOW judgment is unstable
near the threshold values.
HIGH threshold
Measured value
LOW threshold
ON
HIGH
OFF
ON
PASS
OFF
Output
ON
LOW
OFF
Setting value
00.000 to 59.999 (mm)
1
Select the hysteresis setting.
Select [HYS].
Confirm the selection.
2
Change the current value.
The sub-display flashes.
Move from one digit to another.
Change the current value.
Confirm the selection.
ZX-GT User's Manual
Hysteresis
Description
Sets the hysteresis width. (default value: 00.100)
Operation point
Return point
SUB
Setting Output Conditions
67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zx-gif11aZx-gif11Zx-gif41aZx-gif41

Table of Contents