Display and operation panel
Name
(1) Bank 1 indicator
(2) Bank 2 indicator
(3) Zero reset
indicator
(4) Judgment output
indicator
(5) Main display
indicator
(6) Sub-display
indicator
(7) Threshold
switch
(8) Mode
switch
(9) Control keys
ZX-GT User's Manual
Function
This indicator turns ON when bank 1 is selected.
This indicator turns ON when bank 2 is selected.
This indicator turns ON when the zero reset function is enabled.
This indicator lights when "the HIGH threshold <
HIGH LED :
the measured value."
This indicator lights when "the LOW threshold ≤
PASS LED :
the measured value ≤ the HIGH threshold."
This indicator lights when "the measured value <
LOW LED
:
the LOW threshold value."
The main display shows measured values and function names.
Reading Displays p.143
The sub-display shows additional information and function settings
for measurements.
Reading Displays p.143
The threshold switch selects whether to set (or display) the HIGH
or LOW threshold.
The mode switch selects the operation mode.
FUN : Select this mode when setting measurement conditions.
T
: Select this mode when setting thresholds.
RUN : Select this mode when performing measurement.
Use the Control Keys to set the measurement conditions and
switch the display.
List of Key Operations p.143
23
ZX-GT Series

Hide quick links: