Binary Level - Omron ZX-GT User Manual

Zx-gt series smart sensor
Hide thumbs Also See for ZX-GT:
Table of Contents

Advertisement

Binary Level

Adjust the binary level to suit the optical transmittance of the measurement object.
Reference settings are as follows:
• Non-transparent object: 25% (default value)
• Transparent object/non-transparent object: 50% or more
Note
When the measurement mode is the wire position measurement mode or the glass edge
measurement mode, the binary level is automatically set to 50%.
Important
The edge detection state changes when the binary level is changed.
The edge detection state can be verified by the EDGEPOS command.
p.123
Setting value
25 to 90 (%)
1
Select the special setting.
Select [SPCL].
Select [M-LV] or [ALL].
Confirm the selection.
2
Set the binary level.
Select [BIN.LV].
The sub-display flashes.
Move from one digit to another.
Change the current value.
Confirm the selection.
ZX-GT User's Manual
Description
Set the binary level. (default value: 25)
SUB
SUB
Adjusting Detection Conditions
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zx-gif11aZx-gif11Zx-gif41aZx-gif41

Table of Contents