Graphic Screen Creation Window Operations - Omron WS02-LCTC1-E - V2.60 REV 12-2003 Manual

Table of Contents

Advertisement

Creating Graphic Screens
Element
Function block name (model)
Function block
1-Block Send Terminal to Computer
(403)
4-Block Send Terminal to Computer
(404)
AO to Computer (402), AO Terminal
to all nodes (408)
DO to Computer (401), DO Terminal
to all nodes (407)
AO Terminal Settings from
Computer (410)
DO Terminal Settings from
Computer (409)
Display
Setting

4-5-2 Graphic Screen Creation Window Operations

Starting
90
Note If the WS02-LCTK1-EL01 License Key is not connected to the computer printer
port, or even if it is connected, if the License key driver is not installed, you can-
not use the Graphic Builder. (If you try to click the Graphic Builder Button and
change to the Graphic Builder, an error message will be displayed.)
In the Setup Dialog Box, click the Graphic Builder Button.
Function block or ITEM set as send source
Control Block: Tag ITEMs for Basic PID (011), Advanced PID
(012), Batch flowrate capture (014), Indication and Setting
(031), Indication and Operation (032), Ratio Setting (033),
Indicator (034), blended PID (013), 2-position ON/OFF (001),
3-position ON/OFF (002)
Control Block: Basic PID (011), Advanced PID (012),
Indication and Setting (031), Indication and Operation (032),
Ratio Setting (033), Indicator (034), 2-position ON/OFF (001),
3-position ON/OFF (002)
Operation Block: High/Low Alarm (111), Segment Program
2(157), ON/OFF Valve Manipulator (221), Motor Manipulator
(222), Reversible Motor Manipulator (223), Motor Opening
Manipulator (224), Timer (205), Counter (208)
Analog input signals or analog output signals for all Function
Blocks, or analog value parameters
Contact input signals or contact output signals for all Function
Blocks, or contact value parameters
Analog output ITEM for AO Terminal Settings from Computer
(Used to set ordinary analog values. Displays using network
resend monitoring.)
Contact output ITEM for DO Terminal Settings from Computer
(Used to set ordinary contact values. Displays using network
resend monitoring.)
Analog values: Bar graphs, numerical values, tank level
Contacts: Indicators, pumps, valves, pipes
Analog values: Numerical values (using AO Terminal Settings
from Computer)
Contacts: Switches (using DO Terminal Settings from
Computer)
Click here
Section
4-5

Advertisement

Table of Contents
loading