Omron FQ User Manual page 49

Vision sensor
Hide thumbs Also See for FQ:
Table of Contents

Advertisement

Adjusting the Image Timing
The internal timing for taking an image can be set to be delayed in relation to the external trigger signal. This
can be used to adjust the object position in the image, e.g., if an external trigger sensor is used. If the object
position still varies in the image the Position Compensation function must also be used.
[Image] − [Trigger setup] − [Trigger delay]
1
A TRIG signal is input.
Images are input continuously.
2
Select the image with the measurement object in the
center using [
] and [
3
Press the image.
4
Press [OK].
Note
The delay time can be set using the adjustment bar or by directly entering a value.
FQ User's Manual
Delay time
Delay from when the trigger is input until
when Sensor input is started.
].
Move the bar to the left or right.
Or
Directly input the delay time.
Trigger input Sensor
Adjusting the Object Position