Changing the Measurement Region
The region within which the model is searched can be changed. In the default settings, the whole display is set
as the measurement region.
[Inspect] – [Search] − [Modify] – [Settings] Tab Page – [Teach]
1
] − [Insp. region] on the right of the display.
Press [
The [Insp. region] Display will appear.
2
Adjust the size and position of the measurement re-
gion.
• Change the size.
Press the frame at one corner.
The processing time can be shortened by making the
region smaller.
• Change the position.
Drag the figure to move it.
Measurement Data That Can Be Logged
The following values can be logged as measurement data.
Parameter
Setting
Correlation
0 to 100
7-4 Logging Measurement Data and Image Data: p. 98
Errors
Errors in Teaching
A teaching error message will appear if the contrast of the image within the model registration region is too low.
Select a region with a larger contrast between light and dark areas compared to the region that was registered
as the model and re-register it as the model.
FQ User's Manual
Description
This is the measured correlation.
Inspecting with the Search Inspection Item