Omron FQ User Manual page 131

Vision sensor
Hide thumbs Also See for FQ:
Table of Contents

Advertisement

Important
If the cycle time is too long, the PLC may not be able to detect when the BUSY signal is ON. If necessary, turn
OFF W0.00 after a suitable time elapses.
Registering the Measurement Reference Again
The model and reference color can be re-registered with commands from an external device, such as a PLC,
based on the image that was just input when the line process was changed.
Inspection item
Search
Color data
Edge Position, Edge Width, Area
Note
• Application is possibly only from the Run Mode
• If the parameter is applicable to more than one inspection item, it will be re-registered for all inspection items.
Settings
[In/Out] − [I/O setting] − [Input] − [Input mode]
Press [Expand mode].
Wiring
Color
Signal
State
Gray
IN0
OFF
Green
IN1
OFF
Red
IN2
OFF
White
IN3
ON
Purple
IN4
OFF
Yellow
IN5
ON
Orange OUT1 (BUSY)
--
FQ User's Manual
Re-registered data
Model data
Reference color (hue, saturation, and brightness)
None
Description
Command parameter for registering the model
again
Command input for registering the model again
Processing in progress (default)
The signals shown at the left are
used.
Refer to the following information for
signal wiring.
2-4 Wiring: p. 28
Controlling the Sensor from an External Device
127

Advertisement

Table of Contents
loading

Table of Contents