8-1 Operation with Default Configuration

This section describes the basic connections and signal flow with external devices.
With the default settings, the Sensor operates in the following manner.
Trigger Sensor
(1) Measurement
ON
trigger input
OFF
(TRIG signal)
(2) Executing
ON
measurement
OFF
processing
(BUSY signal)
(3) Judgement results
output (overall
judgement: OR
signal)
Important
• Create the ladder program to control the TRIG and IN5 input signals so that they do not turn ON while the BUSY
signal is ON. If not, a TRIG input error will occur and the ERROR signal will turn ON.
• Operation When the Sensor Power Supply Is Turned ON
The BUSY signal will operate as shown below when the Sensor's power supply is turned ON.
Create the ladder program in the PLC or other external device so that the BUSY signal is ignored while it turns OFF,
ON, and OFF again for up to 5 s after the power supply is turned ON.
Power supply
* Depends on the scene data.
Configuring the Operation
The following settings can be selected depending on the system configuration and application.
Type of change
Changing the type of measurement trigger
Changing the output method of the judgement results
Changing the polarity of the BUSY output
114

Operation with Default Configuration

FQ Vision Sensor
(1) Measurement
trigger input
(2) Measurements
performed
The trigger to perform measurements once is turned ON.
ON while measure-
ments are in progress
24 V
0 V
1.5 s
ON
BUSY
OFF
(3) Judgement
results output
You can confirm if measurements are in progress.
Turned ON when overall judgement is NG.
3.5 s*
Sensor system is initializing
Change
Performing continuous measurements
Obtaining individual judgement results
Adjust the judgement output timing
Changing the judgement output ON conditions
Reversing the polarity of the BUSY signal
External device
This signal stays ON until the next
measurement trigger can be input.
Retained until the next
judgement results are
output.
Turns OFF when the
Sensor is ready for
operation.
Reference
p. 116
p. 120
p. 122
p. 124
p. 124
FQ User's Manual