Timing Chart
Output OR0 to OR31 signals are held until the next judgement output.
ON
TRIG signal
OFF
ON
BUSY signal
OFF
Example:
OR0 signal
OR1 signal
*1: The timing for updating the OR signal is when the measurement results are finalized, regardless of the output settings of the BUSY signal
(BUSY output conditions).
Note
The timing for updating the OR0 to OR31 signals and the ON time after judgement processing can be changed.
Adjusting the judgement output timing: p. 122
Settings
[In/Out] − [I/O setting] − [Output]
1
Press [OUT0].
2
Press [OR2 (Item 2 judgement)].
OR2 output signal was assigned to OUT0.
3
Assign the others in the following manner.
OUT1: OR5
OUT2: OR14
FQ User's Manual
ON for 1 ms min.
ON while measurements are
being processed (depends
on BUSY output conditions)
Individual
judgement
Turned ON when individual
judgement is NG.
(Output polarity: ON for NG)
Turned ON when individual
judgement is NG.
(Output polarity: ON for NG)
*1
Setting the Outputs