Screen Display When the Edge Level and Noise Level Are Changing
A bar showing the threshold level moves up and down on the graphic as the edge level/noise level value changes.
A cross-key cursor will also appear at the detected edge position.
Undesired Edge Position Is Automatically Detected When Teaching
Manually set the color of the edge that you want to detect.
[Inspect] – [Edge Position] − [Modify] – [Settings] Tab Page – [Teach]
1
Press [
] – [Color ON/OFF] on the right side of the display.
2
Press [ON].
3
] − [Set color.] on the right of the display.
Press [
4
Draw a rectangle around the color that you want to
use to extract an edge.
The specified color will be extracted.
5
Press [OK] to enter the edge color.
6
Press [TEACH] again.
7
Press [Back].
Note
It is also possible to check the extraction colors or specify them using the color palette.
The RGB values of the extraction color can be checked and adjusted using the color palette.
] − [Color palette], a color palette will appear.
If you press [
Increasing Processing Speed for Edge Position
Make the measurement region smaller to reduce the processing time.
Changing the measurement region: p. 57