8-3 Setting the Outputs

Using the Overall Judgement Result
When the results of the inspection items are judged, if even one individual judgement result is NG, the OR
output signal is turned ON.
Individual judgement results
Inspection
OK
item 0
NG
Inspection
item 1
Inspection
OK
item 31
Note
The overall judgement result output signal can also be turned ON when all individual judgement results are OK.
Changing the judgement output ON condition: p. 124
Wiring
Color
Signal
Black
OUT0 (OR)
Timing Chart
The OR signal that is output is held until the next overall judgement is output.
ON
TRIG signal
OFF
ON
BUSY signal
OFF
OR signal
Note
The timing for updating the OR signal and the ON time after judgement processing can be adjusted.
Adjusting the judgement output timing: p. 122
FQ User's Manual
Overall judgement
NG (OR signal ON)
If there is even one NG judgement,
the overall judgement will be NG
and the output will be turned ON.
Description
Overall judgement (default
assignment)
ON for 1 ms min.
ON while measurements are
being processed (depends
on BUSY output conditions)
Overall judgement
The signals shown at the left are used.
Refer to the following information for signal wiring.
2-4 Wiring: p. 28
Turned ON when overall
judgement is NG.
(Output polarity: ON for NG)
119

Setting the Outputs