Adjusting Image Quality - Omron FQ User Manual

Vision sensor
Hide thumbs Also See for FQ:
Table of Contents

Advertisement

3-2 Adjusting Image Quality

Adjusting the Focus
[Image] − [Camera setup]
1
Display the Camera Setup Display.
The focus can be seen as a numerical value. The higher
the value, the better the focus.
2
Manually adjust the focus using the focus adjust-
ment screw on the Sensor while checking the image
and focus value on the Touch Finder.
In the default settings, the field of view is set to the nar-
rowest setting.
3
Press [Back].
Important
• Turn the focus adjustment screw clockwise or counterclockwise a little bit to make sure that it has not already
reached the dead stop. Do not force the screw if it does not rotate anymore. This will damage the Sensor.
• Do not turn the focus adjustment knob with a force that is greater than 0.1 N·m. This may damage it.
FQ User's Manual
Focus Level
Focus adjustment screw
Turn clockwise to focus on closer objects.
(The field of view will
narrow.)
Turn the screw counterclockwise
to focus on objects at a distance.
(The field of view will widen.)

Adjusting Image Quality