Omron FQ User Manual page 121

Vision sensor
Hide thumbs Also See for FQ:
Table of Contents

Advertisement

Wiring
Color
Signal
Gray
IN0
Green
IN1
Red
IN2
White
IN3
Purple
IN4
Yellow
IN5
Black
OUT0 (OR)
Orange
OUT1 (BUSY)
Timing Chart
ON
IN0 to IN4 signals
OFF
are OFF
ON
IN5 signal
OFF
ON
BUSY signal
OFF
OR signal
1. Turn ON IN5 while IN0 to IN4 are OFF. If status is held while the BUSY signal is OFF, continuous
measurements will begin and the BUSY signal will remain ON while continuous measurements are being
performed.
2. Continuous measurements end when IN5 is turned OFF.
Settings
[In/Out] − [I/O setting] − [Input] − [Input mode]
Press [Expanded mode].
FQ User's Manual
State
Description
OFF
Command parameters for continu-
ous measurements
OFF
OFF
OFF
OFF
ON
Command input for continuous
measurements
--
Overall judgement (default assign-
ment)
--
Processing in progress (default
assignment)
Allow 5 ms min. and then turn ON IN5.
Start continuous measurements
ON while measurements are
being processed (depends on
BUSY output conditions)
The signals shown at the left
are used.
Refer to the following informa-
tion for signal wiring.
Wiring: p. 28
End continuous measurements
Turned ON when overall judgement is NG.
(Output polarity: ON for NG)
Setting the Measurement Trigger
117