7-3 Setting the Outputs

Using the Overall Judgement Result
When the results of the inspection items are judged, if even one individual judgement result is NG, the OR
output signal is turned ON.
Individual judgement results
Inspection
OK
item 0
NG
Inspection
item 1
Inspection
OK
item 31
Wiring
Color
Signal
Black
OUT0 (OR)
Timing Chart
The OR signal that is output is held until the next overall judgement is output.
ON
TRIG signal
OFF
ON
BUSY signal
OFF
OR signal
FQ Short Manual
Overall judgement
NG (OR signal ON)
If there is even one NG judgement,
the overall judgement will be NG
and the output will be turned ON.
Description
Overall judgement (default
assignment)
ON for 1 ms min.
ON while measurements are
being processed (depends
on BUSY output conditions)
Overall judgement
The signals shown at the left are used.
Refer to the following information for signal wiring.
2-3 Wiring: p. 15
Turned ON when overall
judgement is NG.
(Output polarity: ON for NG)