Using the Simple Program Function
Parameters Related to the Simple Program Function
Parameter name
Symbol
ptrn
Program Pattern
prst
Program Start
soak
Soak Time
t-u
Soak Time Unit
wt-b
Wait Band
sktr
Soak Time Remain
Monitor
Note
Program Pattern
130
• The program will start when the Program Start parameter is changed from
RSET to STRT. END will be displayed on the No. 2 display and the output
assigned as the program end output will turn ON after the time set in the
Soak Time parameter has expired in the wait band. The Program Pattern
parameter can be used to select moving to STOP mode or continuing
operation in RUN mode after the program ends.
Set (monitor) values
OFF, STOP, CONT
RSET, STRT
1 to 9999
m (minutes)/h (hours)
OFF or 0.1 to 999.9 (See note 2.)
0 to 9999
(1) Set for Controllers with Thermocouple/Resistance Thermometer Univer-
sal Inputs. Set "None" as the unit for Controllers with Analog Inputs.
(2) The setting unit of the Wait Band parameter is %FS for Controllers with
Analog Inputs and the setting range is OFF or 0.01 to 99.99.
Either of two program patterns can be selected. The simple program opera-
tion will not be performed if the Program Pattern parameter is set to OFF.
■ Pattern 1 (STOP)
Control will stop and the STOP mode will be entered when the program has
ended.
Set point
PV
RSET
STRT
■ Pattern 2 (CONT)
Control will continue in RUN mode when the program has ended.
SP
Set point
PV
RSET
STRT
Unit
---
---
min or h
---
C or F (See notes 1
and 2.)
min or h
Soak time
END display
END output
Automatically switches
from RUN to STOP mode.
Soak time
END display
END output
RUN mode continues.
Section 4-15
Display level
Initial setting level
Operation level
Adjustment level
Advanced function set-
ting level
Adjustment level
Operation level
Wait band
Wait band
Wait band
Wait band

Advertisement