Omron CS1W-SLK11-21 - 06-2004 Manual page 86

Sysmac link units
Table of Contents

Advertisement

CX-Programmer Procedures
Creating Data Link Tables
Starting the Data Link Editor
1,2,3...
Making Manual Settings
without Using the Data
Link Table Engineer
2. Open the CX-Server file (*.CDM) in CX-Net or create a new file in CX-Net
by selecting Project and then Open in CX-Net. In this example, Sam-
ple.cdm is used as the file name. The following dialog box will be displayed.
Create the data link tables for each node entered in the CX-Server file. In this
example, the data link tables are created automatically using the Data Link
Table Engineer, then the parameters are changed manually.
1. Select Data Link and then Editor. A dialog box for selecting the type of
data link will appear.
2. Select SYSMAC LINK Data Link Table and then click the OK button. The
Data Link Editor [SYSMAC LINK] will start.
You can make Manual Settings without using the Data Link Table Engineer.
Create data link tables manually in the following cases.
• The send area size is different for each node participating in the data link.
• The send node order is not the same as the order of node addresses.
• There are nodes that are not receiving data.
Section 4-12
69