9.4 Table of alarms

Alarm
Description
No alarm
E00
Canister fill pump TRIAC faulty
E21
"Sensing" circuit of canister fill pump TRIAC faulty
E22
Frequency of signal from conductimetric sensor too
E31
high
Frequency of signal from conductimetric sensor too
E32
low
Appears when displaying the last alarm. If position
E33
8, NOT OK.
Door closure sensor
E45
Motor power TRIAC short-circuited
E51
Motor overload cut-out tripped
E52
"Sensing" circuit of motor TRIAC faulty
E53
Motor stopped
E54
2008-03 ADL
Possible fault
---
Faulty wiring; Main circuit board faulty
Main circuit board faulty
Main circuit board faulty
Faulty wiring; Brushes worn/faulty; Main circuit
board faulty.
Faulty wiring; Brushes worn/faulty; Main circuit
board faulty.
Door lock faulty; Faulty wiring; Main circuit board
faulty
Motor faulty; Faulty wiring; Main circuit board
faulty
Motor faulty; Motor overload cut-out tripped; Faulty
wiring; Main circuit board faulty
Main circuit board faulty
Excessive wash load; voltage too low;
motor/transmission system jammed
36/58
Remedy / Machine status
Alarm enabled only in diagnostics mode
Alarm enabled only in diagnostics mode
Disconnects the power supply to the heating
unit and interrupts reversal of rotation. If the
problem disappears, the alarm is stored in
memory and the cycle resumes. If the fault
persists after several attempts to restore the
power supply (about 35 minutes), alarm E51
Cycle paused after a number of attempts by
599 70 66 79
---
Cycle stopped
Cycle stopped
Cycle stopped
Cycle stopped
Cycle stopped
is generated.
Cycle stopped
the motor to re-start
Reset
command
---
OFF
OFF
---
OFF
---
OFF
OFF
OFF
OFF
START