Processing unit
Table of Contents

Advertisement

Field and Zone
Initial Field
State at End
Command
Command Sequence
and Zone State
of Command
Read Count, Key and Data
None
Cl
D4
Read Key and Data
None
Cl
D4
After Search I D
C4
D4
Read Data
None
Cl
D4
After Search ID
C4
D4
After Search Key
K4
D4
Write Count, Key and Data
Search Equal ID
C4
D4
Search Equal Key
K4
D4
Write RO
D4
D4
Write Count, Key and Data
D4
D4
Write Key and Data
Search Equal ID
C4
D4
Write Data
Search Equal ID
C4
D4
Search Equal Key
K4
D4
Search ID
None
Cl
C4
Search Key
None
Cl
K4
After Read or Search ID
C4
K4
Search Key and Data
None
Cl
04
After Read or Search ID
C4
D4
Search Home Address
None
HA
H4
Read RO
None
HA
D4
After Read or Search Home Address
H4
04
Write RO
Write Home Address
H4
D4
Search Equal Home Address
H4
D4
Read Home Address
None
HA
H4
Write Home Address
None
HA
H4
Read Initial Program Load
None
Cl
D4
Read Count
None
Cl
C4
Erase
Search Equal ID
C4
D4
Search Equal Key
K4
D4
Write RO
04
D4
Write Count, Key and Data
04
04
No Operation
None
Reset Condition
Figure 1-116. 2311/DAC Track Orientation Field and Zone State Summary