8-3.

Accessing User Setup Menu

STAT
AC
AC Communication Amperage Selection (Dynasty Only)
Use Encoder to select between [HIGH] OR [LOW] AC commutation amperage. Default is High.
Application: Use High commutation amperage when a more aggressive arc is preferred. Use Low commutation
amperage when a less aggressive and quieter arc is preferred.
.
A complete Parts List is available at www.MillerWelds.com
3
4
USER
MENU
OFF
COM.A
1
5
2
TIG Start Parameters
1
Amperage Button
2
Gas/Dig Button
3
Parameter Display
4
Setting Display
5
Encoder Control
To access the User Functions, press
and hold the Amperage (A) and the
Gas/DIG
controls
until
[USER]
[MENU] is displayed. To scroll through
the user menu functions, press and re-
lease the Gas/DIG control.
Rotate Encoder to adjust parameter
setting.
To exit user menu, press Amperage
and Gas/DIG controls at the same time
and then release, or turn power off.