The serial number and rating information for the power source is located on the front of the machine. Use the rating labels to determine input power
requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual.

4-2. Specifications

.
Do not use information in unit specifications tables to determine electrical service requirements. See Sections 5-14 and 5-15 for information on
connecting input power.
.
This equipment will deliver rated output at an ambient air temperature up to 1045 F ( 405 C).
A. Dynasty 400 Models
.
Do not use information in unit specifications table to determine electrical service requirements. See Section 5-14 A for information on connecting
input power.
Welding Amperage
Range
3-400*
*Welding range for Stick process is 5-400 amperes. For TIG, the amperage range is tungsten diameter dependent (see Section 6-3).
** Arc starting device is designed for manual guided operations.
*** Low open-circuit voltage while in TIG Lift Arct, or while in Stick with low open-circuit voltage selected.
♦ Normal open-circuit voltage (75) is present while in Stick with normal open_circuit voltage selected.
Rated Welding
Input
Power
Output
250 A @ 30 Volts,
100% Duty Cycle
300 A @ 32 Volts,
Three
60% Duty Cycle
Phase
400 A @ 36 Volts,
20% Duty Cycle
200 A @ 28 Volts,
100% Duty Cycle
250 A @ 30 Volts,
Single
Phase
60% Duty Cycle
300 A @ 32 Volts,
20% Duty Cycle
.
This unit is equipped with Auto-Line
primary input voltage from 190 to 625 volts, single-or-three-phase, 50 or 60 hertz. It also adjusts for voltage spikes within the entire range.
Notes
OM-275857 Page 12
.
A complete Parts List is available at www.MillerWelds.com
SECTION 4 − SPECIFICATIONS
Max Open Circuit
Low Open-Circuit
Voltage (Uo)
Voltage (Uo)
75
208 V
230 V
28
25
36
33
49
55
40
36
52
47
67
60
.
Auto-Line is an internal inverter power source circuit that automatically links the power source to any
Rated Peak Striking
Voltage (Up)
10-15***
14KV**
Amperes Input at Rated Load Output 50/60 Hz
380 V
400 V
460 V
15
14
19
19
29
28
20
26
33
IP Rating
23
575 V
KVA
13
10
10.3
16
13
13.1
24
19
19.4
17
13
8.2
22
17
10.9
28
22
13.9
KW
9.8
12.5
18.6
7.5
9.9
12.7