5-3. Selecting Cable Sizes*

NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is 100
ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine cable size.
Welding Amperes***
100
150
200
250
300
350
400
500
This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
*
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
2
( ) = mm
for metric use
*** Select weld cable size for pulsing application at peak amperage value.
****For distances longer than 100 ft (30 m) and up to 200 ft (60 m), use direct current (DC) output only. For distances longer than those shown
in this guide, call a factory applications rep. at 920-735-4505 (Miller) or 1-800-332-3281 (Hobart).
Notes
OM-275857 Page 20
.
A complete Parts List is available at www.MillerWelds.com
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit Not Exceeding
100 ft (30 m) or Less****
10 − 60% Duty Cycle
60 − 100% Duty Cycle
2
AWG (mm
)
4 (20)
3 (30)
3 (30)
2 (35)
1 (50)
1/0 (60)
1/0 (60)
2/0 (70)
2
AWG (mm
)
4 (20)
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
2/0 (70)
3/0 (95)
4/0 (120)
150 ft
200 ft
(45 m)
(60 m)
10 − 100% Duty Cycle
2
AWG (mm
)
4 (20)
3 (30)
2 (35)
1 (50)
1 (50)
1/0 (60)
1/0 (60)
2/0 (70)
2/0 (70)
3/0 (95)
3/0 (95)
4/0 (120)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
Ref. S-0007-L 2015−02 (TIG)