7-3.

Accessing User Setup Menu

TUNG
RMT
HOTS
OM-275857 Page 48
.
A complete Parts List is available at www.MillerWelds.com
3
4
USER
MENU
3/32
2T
ON
1
5
2
Tungsten Diameter Selection
Each tungsten size has preset starting parameters spe-
cific to that diameter for optimized starting. Range is
0.020−3/16 in. or 0.5−4.8 mm. To manually set starting
parameters, see Section 15-3.
Output Trigger Mode Functions
See Section 9-3 to reconfigure RMT functions.
Arc Starting Mode Selection (Stick)
[HOTS] [ON]
Provides additional amperage while striking the elec-
trode to prevent the electrode from sticking.
[HOTS] [OFF]
No additional starting amperage to assist in starting the
electrode.
1
Amperage Button
2
Gas/Dig Button
3
Parameter Display
4
Setting Display
5
Encoder Control
To access the User Functions,
press and hold the Amperage (A)
and the Gas/DIG controls until
[USER] [MENU] is displayed. To
scroll through the user menu func-
tions, press and release the Gas/
DIG control.
Rotate Encoder to adjust paramet-
er setting.
To exit user menu, press Amperage
and Gas/DIG controls at the same
time and then release, or turn power
off.