5-8.

115 Volts AC Cooler Receptacle, Supplementary Protector CB1, And Power Switch

3
5-9.

Gas Connections

OM-275857 Page 26
.
A complete Parts List is available at www.MillerWelds.com
4
1
1
2
3
2
1
AC Cooler Receptacle
Receptacle RC2 supplies 115 V 4A
of single-phase power.
.
RC2 is a designated use re-
ceptacle intended only for sup-
plying AC power to a Miller-ap-
proved cooler.
2
Supplementary Protector CB1
CB1 protects cooler receptacle
from overload. If circuit breaker
opens, the receptacle does not
work. Press
button
to
reset
protector.
3
Power On/Off Switch
805593-A
1
Gas Fitting
Fittings have 5/8-18 right-hand
threads.
2
Cylinder Valve
Open valve slightly so gas flow
blows dirt from valve. Close valve.
3
Regulator/Flowmeter
4
Flow Adjust
Typical flow rate is 15 cfh (cubic feet
per hour).
Connect customer supplied gas
hose between regulator/flowmeter
and gas fitting on rear of unit.
Tools Needed:
11/16, 1-1/8 in.
805593-A