9-2. Sequencer And Weld Timer

INTL
INTL
ISLP
FSLP
FNL
FNL
WELD
OM-275857 Page 56
.
A complete Parts List is available at www.MillerWelds.com
20A
OFF
OFF
OFF
10A
OFF
OFF
Sequencer Control With Weld Timers ON
This function is available while using the TIG
process, but is disabled if a remote foot or fin-
gertip control is connected while in the RMT
STD mode. When active, the sequencer con-
trols the following parameters of the weld
cycle:
Initial Amperage
Range is 3−400/5−800 amps
Initial Time*
Range is OFF to 25.0T (seconds)
Initial Slope Time
Range is OFF to 50.0T (seconds)
Final Slope Time
Range is OFF to 50.0T (seconds)
Final Amperage
Range is 3−400/5−800 amps
Final Time*
Range is OFF to 25.0T (seconds)
.
When a remote switch is connected to the
welding power source, use the remote
switch to control the weld cycle. Amperage
is controlled by the welding power source.
*
Enabled features with weld timer On (see
Section 9-1).
Weld Timer
With Weld Timer enabled, press Amperage (A)
button, and rotate Encoder to set weld time.
Range is Off or 0.1−99.9 and 100−999 (sec)