3-5.
Weld
Output
Terminals And
Selecting
Cable Sizes
A
ARC WELDING
can cause
Electromagnetic
Interference.
~~$
To reduce
possible interference, keep
weld cables
as
short
as
possible,
dose
together,
and down
low,
such
as on
the
floor.
Locate
welding operation
100 meters from
any sensitive electronic
equipment.
Be
sure
this
welding
machine is installed
and
grounded according
to
this manual. If interference still
occurs,
the
user
must take extra
measures
such
as
moving
the
welding
machine,
using
shielded
cables,
using
line
filters,
or
shielding
the work
area.
Weld
Output
Terminals
Welding
Amperes
Total Cable
(Copper) Length
In Weld
Circuit
Not
Exceeding
100
(30 m)
Or Less
150ft
(45 m)
200ft
(60 m)
250ft
(70 m)
300ft
(90 m)
350ft
(105 m)
400ft
(120 m)
1060%
Duty
Cycle
60100%
Duty
Cycle
10
100%
Duty Cycle
+
Output Receptacles
100
4
4
4
3
2
1
1/0
1/0
150
3
3
2
1
1/0
2/0
3/0
3/0
200
3
2
1
1/0
2/0
3/0
4/0
4/0
250
2
1
1/0
2/0
3/0
4/0
2-2/0
2-210
300
1
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
350
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
2-4/0
400
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-4/0
2-4/0
500
2/0
3/0
4/0
2-2/0
2-3/0
2-4/0
3-3/0
3-3/0
600
3/0
4/0
2-2/0
2-3/0
2-4/0
3-3/0
3-4/0
3-4/0
Weld cable size
(AWG)
is based
on
either
a
4 volts
or
less
drop
or a
current
density
of
at
least 300 circular mils per ampere.
S-ooo7-D
3-6.
Remote 14
Receptacle
Information
~$~ł~
~/
ST-801
192
~aom 14
Socket*
Socket Information
24
VOLTS AC
OUTPUT
(CONT~TOR)
A
24 volts
ac.
Protected
by
circuit breaker CB2.
B
Contact closure to A
completes
24 volts
ac
con
tactor
control circuit.
115 VOLTS AC
OUTPUT
(CONT?CTORJ
I
115 volts
ac.
Protected
by
circuit breaker CB1.
J
Contact closure
to I
completes
115 volts
ac con
tactor control
circuit.
REMOTE
OUTPUT
CONTROL
C
Output
to remote
control;
0 to +10 volts
dc,
+10
volts dc in MIG mode.
D
Remote control circuit
common.
E
0 to +10 volts dc
input
command
signal
from
re
mote control.
A/V
AMPERAGE
VOLTAGE
H
Voltage
feedback;
1
volt dc per 10
output
recep
tade volts.
F
Current
feedbacl
+1 volt
dc per 100 amperes.
M
CC/CV select
(CCICV
models
only).
GND
G
Circuit
common
for
24
and 115 volts
ac
circuits.
K
Chassis
common.
The
remaining
sockets
are
not used.
.
OM-193
084
Page