Cli Number; Reporting Options; Tx Format Dest 1 - Bosch Solution 16plus Installation Manual

Hide thumbs Also See for Solution 16plus:
Table of Contents

Advertisement

Solution 16
plus
Installation Manual
It is important to realise that this code is only used to start the
connection process. Once a connection is established, the voice
module will ask the user to enter their PIN before they will be
able to control the panel. The Voice Access Code is shared by all
users who need this type of access to the panel. See the CM100
documention for more details.
1)
Press [MENU] + [5] + [3] + [6]. The keypad will display the
current DTMF options.
Voice Access Code N001
9#
Press 0-9 OK to SAVE
Using the numeric keys enter the new Voice Access Code then
2)
press [OK] to save and exit or press [MENU] to exit without
saving.
Comms > Remiote Access >

CLI Number

1
First
Number
1
Second
Number
1
Third
Number
CLI Numbers (Call Line Identification) allows the Solution control
panel to answer an incoming call only when the control panel
identifies that the incoming call is from any one of the three
CLI numbers programmed. Up to three different CLI telephone
numbers can be programmed, each having a maximum of 32
digits.
1)
Enter [MENU] + [5] + [3] + [7]. The keypad will display
information for CLI number 1.
CLI Telephone Number 1
Press  0-9 OK to SAVE
2)
Using the numeric keys, enter all the digits for CLI number 1.
You can change a single digit by scrolling the cursor left or
right. For special characters including, pause, * or #, use the
up and down arrow keys.
3)
Press [OK] to program CLI number 2.
CLI Telephone Number 2
Press  0-9 OK to SAVE
Using the numeric keys, enter all the digits for CLI number 2 .
4)
Press [OK] to program CLI number 3.
5)
9-10
Comms Programming
MENU 5-3-7
Digits
Digits
Digits
When finished Press [OK] to save and exit or press [MENU] to
6)
exit without saving.
i
Up to 3 Phone numbers can be entered for CLI Call Line
Identification for remote access detection. You must enter STD
code plus the compete number for this option to work. Press [OK]
Note
after each telephone number is entered to save and move to the
next number.
RE POR TING OPTIONS
Comms > Dialler Reporting >

TX Format Dest 1

0 = Disable
1 = Contact ID
7 = Domestic
2 = SIA
8 = Voice
3 = Serial STU
9 = SIA+
4 = GSM
10 = Reserved
5 = WEB MAIL
11 = Reserved
6 = SMS
12 = Reserved
This menu allows you to program the transmission format or
language the panel will use to send event reports to Destination
32
1. The panel has two separate destinations that reports can be
sent to and each one can be set to use a different transmission
format depending on the application.
32
At factory default, all reports are routed to Destination 1.
1)
Press [MENU] + [5] + [4] + [0]. The keypad will display the
32
current Transmission Format for Destination 1.
TX Format Dest 1 P001
01 - Contact ID
Press  0-9 OK to SAVE
2)
Use the up and down arrow keys to select the Transmission
Format required then Press [OK] to save and exit or press
[MENU] to exit without saving.
i
Option 14 - SMS - No Parity, is only available in version 1.02 or
higher.
Note
Comms > Dialler Reporting >
TX Format Dest 2
0 = Disable
1 = Contact ID
7 = Domestic
2 = SIA
8 = Voice
3 = Serial STU
9 = SIA +
4 = GSM
10 = Reserved
5 = WEB MAIL
11 = Reserved
6 = SMS
12 = Reserved
This menu allows you to program the transmission format or
language the panel will use to send event reports to Destination
2.
Press [MENU] + [5] + [4] + [1]. The keypad will display the
1)
current Transmission Format for Destination 2.
MENU 5-4-0
13 = Reserved
14 = SMS - No Parity
15 = Reserved
MENU 5-4-1
13 = Reserved
14 = SMS - No Parity
15 = Reserved
Bosch Security Systems 05/10 BLCC100I
1
1

Advertisement

Table of Contents
loading

Table of Contents