FE AT U RES
Listed below are the main features of the Solution 16
Panels.
Individual Box Tamper Circuit Monitoring
Telephone Line Busy Tone Detect
RAS Intelli-connect® CLI Caller Line Identification
Daylight Savings Auto Time Adjust
Senior Watch
System Maintenance Interval Reminder
System Weekly Test Reminder
Area Inactivity Interval
Temporary Pin Code
Dual Reporting
Alarm Report Abort/cancel Options
8 Programmable Holiday Calendars
8 Programmable Schedules
8 On-board Zones (Exp To 16 Wired or Wireless)
Fire Alarm Verification
48 Pin Codes
3 Supervised High Power Digital Outputs
1 Relay 2 Amp Form (C) Contact (Expandable to 5)
Supervised Siren Driver
Partitionable To 4 Areas
Dialler Reports SIA, Contact ID, SMS and Email Formats
Supervised LAN Keypads (Maximum 8 Keypads)
Keyswitch Input
256 History Event Memory
Fully Menu Text Programmable
Programmable Via Solutionlink Software(Remote/Direct)
Telephone Line Fail Monitor
Time Executed Functions
60 Output Event Types
Exit Restart
Expansion Module SuperSolution
DTMF Tone Decoder Built In
Remote and Auto Arming
Bosch Security Systems 05/10 BLCC100I
OVE RVIE W
Control
plus
Zones
The Solution 16
zones of protection. Zone programming determines the panel's
response to open/short and tamper conditions on the zone
loop.
Areas
The control panel supports up to 4 separate areas. You can
assign all zones to a single area, or you can assign each zone to
a combination of different areas.
You can arm and disarm the control panel by area, alternatively,
you can arm and disarm several areas at the same time.
Dialler
The control panel has a built-in dialler to send reports to the
receiving party (ie. Security company monitoring station,
mobile phone etc).
Keypads
You can connect a maximum of 8 fully supervised keypads to
the control panel. The available current affects the total number
of keypads that you can connect without the need to provide
additional power supplies.
History Log
The control panel can store up to 256 history events from
all 8 areas. All events are stored in the log, even if they are
programmed not to report via the on-board dialler.
You can view the control panel's history log via keypad, serial
printer (optional), or by connection of a personal computer
(direct/remote) using the SolutionLink upload/download
software.
Programming
You can program the Solution 16
a personal computer using the SolutionLink upload/download
software.

Overview

control panel provides up to 16 separate
plus
either by a keypad or using
plus
SECT ION 1
1-1