Area Programming; Area Status; Turn Area On/Off - Bosch Solution 16plus Installation Manual

Hide thumbs Also See for Solution 16plus:
Table of Contents

Advertisement

T
he Solution 16
has 4 different areas each with its own
plus
specific programmable options.
Under the commands menu you can interrogate the status of
an area, turn chime mode on/off, move to an area or arm and
disarm a specific area.
The customer account number is programmable for each
individual area as well as input, output and general options.
Each time you are presented with an option that is area specific,
the menu will prompt you to specify the area first.
Partitioning
The Solution 16
control system can be partitioned into 4
plus
individual areas. Each area has its own individual properties
which determine how the area operates. The default name for
AREA-1 is "Security System" and it can be changed to any other
name using the area properties menu. All zones and users are
assigned to AREA-1 so no assigning of users or zones is required
for non partitioned systems by default.
To create an area, assign one or more zones to the area of your
choice. A zone can only belong to one area and any number
of zones can belong to a single area. Each area operates
independently from other areas as if it were another security
panel and there are numerous options available to tailor just
how the entire system should operate. If you require a common
area that automatically arms when all other areas are armed,
and disarms as soon as any other area is disarmed, then Area 1
can be set as a common area. To make area 1 a common area,
set the option under MENU 7-7-1 — Area Options.
All keypads connected to the system have the ability to display
the arm/disarm condition of every area at the same time using
the area icons on the display. This is selectable per keypad under
MENU 6-1-4 — General Options.
Once you log onto a keypad using your pin code + OK the
system knows who you are and will allow you to use the left
arrow key to move from the current area to the next area that
your assigned to. To move areas without having to enter your
code select the option under MENU 7-7-1 — Area Options and
then simply step through all the available areas using the arrow
keys. Each keypad is assigned a home area and will automatically
revert back to this area after 60 seconds.
The system outputs must be configured to operate for their
corresponding areas. The external siren, internal siren and
strobe outputs are defaulted to output index 0 and will operate
for any area . If you want the output to operate for multiple
areas then the output index needs to be set to 0.
Bosch Security Systems 05/10 BLCC100I

Area Programming

Example: Simple Two Area System
1) Assign zones to area 1 and area 2
2) Assign the home areas for the keypads
3) Assign users to areas
4) Set outputs to operate individually or common for all areas.
5) Set account code for each area
6) Set options,
Code to Change areas or just arrow key
Which keypads to display area icons
Reset Sirens by any user on any area
ARE A COMMA ND S
Areas > Commands >

Area Status

This command allows you to view the condition of any area
in the system. In the following example Area 1 has the name
"Security System" and it is currently in the Disarmed State.
1)
Enter [MENU] + [2] + [0] + [0] and select the area to view and
press [OK].
Security System A001
Disarmed
Press OK or MENU
Areas > Commands >

Turn Area On/Off

This command allows you to turn on or off areas. If an area
has already been turned All On or Part On, a 'tick' () will be
displayed on the right side of the area name.
Enter [MENU] + [2] + [0] + [1] and select the area and press [OK]
1)
to change the current state.
A001 Security System 
A002 Area 2 Name
A003 Area 3 Name 
Press

SECT ION 6
-
-
-
MENU 2-0-0
-
-
MENU 2-0-1
OK ON OFF MENU