Solution 16
plus
Installation Manual
When installing large modules you should fit 5
mounting clips as shown.
Clip 5 provides support under the main terminal
block only. No screw is fitted.
1
4
CABLE ENTRY (REAR)
MODULE
SPACE 2
CABLE ENTRY (REAR)
MODULE
SPACE 4
CABLE ENTRY (REAR)
1
MODULE
SPACE 6
4
When installing small modules, you should
fit 4 mounting clips as shown.
Figure 7: MW710 Configuration Examples
CONNE CTIN G P OW ER TO TH E PANEL
For normal operation, the panel requires both A.C. and DC
power sources. The A.C. source can be provided either by an
external adapter or by an internal transformer depending on
the model and country of sale.
When connecting using the A.C adapter, feed the cable in to the
enclosure and terminate the wires on the removable terminal
block supplied before connection it to the PCB.
If using a 3 wire Adaptor, then the earth wire should also
be terminated onto the terminal block. Always check the
orientation of the terminal block with the PCB markings before
connecting it to the PCB.
2-4
Installing the Hardware
2
MODULE
SPACE 1
5
3
MODULE
SPACE 3
MODULE
SPACE 5
2
MODULE
SPACE 7
3
CONNE C TING THE BATTERY
The panel is supplied with a set of battey leads to suit the
chosen enclosure. Connect the Red Battery lead to the Battery
(+) terminal and the Black Battery lead to the Battery (-) terminal
on the PCB.
Once terminated onto the PCB connect the other end of the
leads to the battery paying attention to the polarity.

A .C . MAINS TR ANSFORM ER OPTI ON

On models with an internal transformer, a
connection shall be made to the mains supply. See Figure 8. This
must be completed by a suitably qualified electrician according
to the applicable wiring standards and regulations.
Next connect the transformer output wires (red) to the
removable terminal block supplied and then connect it to the
PCB. Always check the orientation of the terminal block with
the PCB markings before connecting.
i
For permanently connected equipment, a readily accessable
disconnect device shall be installed in a location near to the
equipment.
Note
Transformer Output
(Red Wires)
A
Transformer
D
(Blue Wires)
A
B
A = PCB Mounting Clip Holes
B
= Enclosure Mounting Holes
C
= Fused Terminal Block
D
= Transformer
Figure 8: Internal Transformer Connection Diagram
permanent
Wiring must be carried out by
a licensed electrician following
applicable wiring standards
Input
TRANSFORMER
220 - 240V A.C.
50-60Hz 150mA
FUSE
8AG - 250V
250mA MAX
NEUTRAL
EARTH
ACTIVE
C
Bosch Security Systems 05/10 BLCC100I
A
A