Tamper On Short
Reserved
Response Time 500msec
Press  OK ON OFF MENU
2)
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
3)
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Tamper On Short
Setting this option will cause any Zone which become shorted to
report a tamper alarm condition for the zone.
Response Time 500ms
Setting this option will increase the response time for all zones to
500ms.
Keyswitch Open/Close
This feature allows you to select whether or not a zone
programmed as a Keyswitch Zone, will send opening and
closing reports. The default is set to Off.
Alarm On Tamper
This option allows tamper circuits on RF sensors and hardwire
zones to sound an alarm when faulted when their corresponding
area is turned off (disarmed). This option is available in version
1.02 and higher.
Inputs > PGM Input >
Input Type
0 = Disabled
1 = Latching - On/Off (RF Relay)
2 = Momentary - On/Off (RF Relay)
3 = Digiflex RF On/Off
4 = Bosch Serial RF Receiver
This menu option is used to configure the systems programmable
input terminal. Various devices can be connected including
keyswitches of radio controlled relays etc. When RF zones are
required you need to connect the RF receiver to this input
Connect keyswitch between Input terminal and GND. See
Wiring Diagrams in Section 3 for various connection diagrams.
1)
Press [MENU] + [3] + [5] + [0]. The keypad will display the
current input type (Default = 0 Disabled).
Input Type P001
00 - Disabled
Press  0-9 OK to SAVE
2)
Use the up and down arrows to select the required Input
Device Type then press [OK] to save and exit or press [MENU] to
exit without saving.
Bosch Security Systems 05/10 BLCC100I
MENU 3-5-0
0
5 = Crow Serial RF Receiver
6 = Ness Serial RF Receiver
7 = Inovonics Serial RF RX
8 = Secure Wireless RF RX
Solution 16
plus
Installation Manual
i
The Latching and Momentary On/Off modes are active low, and
when triggered, they will automatically force arm the area.
Note
Inputs > Tamper Inputs >
Tamper Options
1
Display Panel Tamper
2
Report Panel Tamper
3
Audible Panel Tamper
4
Display Expander Tamper
5

Report Expander Tamper

6

Audible Expander Tamper

7
Reserved
8
Reserved
This menu programs how the various system tamper inputs behave
when faulted. These dedicated tamper inputs are active 24 hours a
day when enabled.
Press [MENU] + [3] + [6] + [0]. The keypad will display the
1)
current tamper options.
 Display Box Tamper
 Report Box Tamper
 Audible Box Tamper
Press  OK ON OFF MENU
2)
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
3)
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Display Cabinet Tamper
Setting this option allows the keypad to display a trouble condition
when the tamper circuit that monitors the systems cabinet is faulted.
The trouble condition will clear when the tamper circuit has restored.
Report Cabinet Tamper
Setting this option allows the panel to send a Cabinet Tamper report
when the cabinet tamper circuit is faulted. A Cabinet Tamper Restore
report will be sent when the tamper circuit has restored.
Audible Cabinet Tamper
Setting this option will cause the panel to sound the sirens when the
cabinet tamper circuit is faulted.
Display Expander Tamper
Setting this option causes the system to display tamper events which
have occured on peripheral modules.
Report Expander Tamper
Setting this option enables peripheral tamper reporting.
Audible Expander Tamper
Setting this option causes the system to trigger an audible alarm
when a peripheral tamper is triggered.
Input Programming
MENU 3-6-0
Y
Y
Y
N
N
N
N
N