Bosch Solution 16plus Installation Manual page 91

Hide thumbs Also See for Solution 16plus:
Table of Contents

Advertisement

Greeting On Arm
Setting this option configures the keypad to display a farewell
greeting when the user arms an area. The greeting will include the
user name if programmed.
Greeting On Disarm
Setting this option configures the keypad to display a welcome
greeting when the user disarms an area. The greeting will reflect the
time of day and include the user name if programmed.
™ Good Morning Greeting = 00:00 to 11:59
™ Good Afternoon Greeting = 12:00 to 17:59
™ Good Evening Greeting = 18:00 to 23:59
Enable Rear Tamper
Setting this option enables the panel to trigger an alarm when the
keypad's inbuilt tamper circuit becomes faulted. A tamper alarm
report will be sent to the base station, a tamper alarm restore will be
sent when the tamper has been reset.
For this option to work, the keypad model being used must have the
on-board tamper switch fitted.
PIN To Change Area
Setting this option will prevent a user from switching between
different areas on the keypad unless they enter a valid user PIN.
When this option is not set, users will be able to change the keypad
view to all other areas in the system regardless of whether or not they
have access to those areas.
Home Area Only
Setting this option will force the keypad to display only it's assigned
home area information. Therefore a user cannot toggle (or move) the
keypad display to show that of a different area when the system has
been partitioned.
Report Keypad Temperature
This option sets the keypad to report a temperature alarm to the base
station if the keypads temperature falls below or rises above the
minumum and maximum temperatures programmed in
MENU 7-7-3 — Keypad Hi/Lo Temp.
An output can be programmed to operate when a keypad hi/low
temperature fail condition occurs irrespective of whether or not this
option is set.
See MENU 6-1-5 — Beeper Options to set the keypad to always show
the current temperature in the display.
Display Area ICON Indicators
This option sets the keypad to show the AREA ICON indicators in the
keypad display at all times. The Icons show the status of all areas on
the system without having to press any keys.
When the Area Icon is ON the corresponding area is armed and when
the Area Icon is OFF or not visible the corresponding area is disarmed.
Security System
DISARMED
Thu,Jan,05 11:22 am
Bosch Security Systems 05/10 BLCC100I
Devices > Keypads >
Beeper Options
1
2
3
4
5
6
7
8
The above options can be configured independantly for each
keypad fitted to the system.
1)
2)
3)
Trouble Alert Beeps
Setting this option will cause the keypad to sound a trouble alert tone
to notify the user that the panel has a trouble condition that needs to
be rectified. Press the [OK] to acknowledge the trouble condition and
stop the alert tone. Press the down arrow for more information on the
trouble condition.
i
Note
Entry Warning
Setting this option will cause the keypad to sound an entry warning
alert tone when the entry timer is running. The tone will stop when a
key is pressed or when the entry time expires.
Exit Warning
Setting this option will cause the keypad to sound an exit warning
alert tone when the exit timer is running. The tone will stop when the
timer expires.
Chime Tone
Setting this option will cause the keypad to sound a chime alert tone
when a chime zone is faulted. Chime zones are active when the area
is disarmed and are typically used to monitor the front door of a shop.
The chime alert tone will stop when the zone reseals.
Display Temperature
22ºC
Setting this option configures the panel to always show the current
keypad temperature in the display. Each keypad can be set to display
its own temperature. It is possible to trigger a temperature alarm
based on the keypad temperature. See MENU 7-7-3 — Keypad Hi/Lo
Temp for more information.
Solution 16
plus
Installation Manual
Trouble Alert Beeps
Entry Warning
Exit Warning
Chime Tone
Display Temperature
PIN Arming Not Allowed
Installer PIN Not Allowed
Show Alarm When Armed
Press [MENU] + [6] + [1] + [5] and use the up and down arrows
to highlight the keypad in the list then press [OK].
 Trouble Alert Beeps
 Entry Warning
 Exit Warning
Press  OK ON OFF MENU
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
See MENU 7-7-1 — Area Options if you would like to delay the
audible trouble alert tone during the night when the panel is
used in residential applications.
Device Programming
MENU 6-1-5
Y
Y
Y
Y
N
N
N
N
10-3

Advertisement

Table of Contents
loading

Table of Contents