Verify Proper Fireplace Operation

15.
1. With the gas line installed, inspect the system before closing the front of the unit.
2. Follow the pilot lighting instructions:
Electronic Systems (Pages 61-64)
NOTE: When lighting the fireplace for the first time, it will take a few minutes for the gas line to purge itself of air.
When purged, the pilot and burner will light and operate as indicated. Subsequent lighting of the fireplace will not
require purging. Inspect the pilot flame (carefully remove logs, if necessary).
Electronic Fireplace Inspection
To light the burner, turn ON the wall or remote control switch. Ensure the igniter lights the pilot. The pilot flame
should engulf the flame rod (Figure 33, Page 41).
Figure 33 - Electronic Pilot
Flame Rod
Initialize the Remote Control System for the First Time
14.
1. Install the four (4) AAA batteries.
NOTE: Check the polarity (+/-) of the batteries and insert them into the battery bay as indicated on the battery
cover.
NOTE: See Operation Instructions provided with the remote control.
Figure 34 - Remote Control
Igniter
Pilot Hood
ON
Cont.
Pilot
SET
S M T W T F S
P1
P2
A
B
MODE/SET
OFF
MODE Zone
ROOM
ROOM TEMP Zone
°
°
SET TEMP Zone
USB
PROGRAM
TIME/PROG Zone
P2
:
AM
P2
PM
LIGHT Zone
FLAME Zone
AUX
AUX Zone
FAN Zone
DOWN Button
MODE/SET Button
UP Button
MODE/SET
BACK
BATTERY
COMPARTMENT
BACK
Installation
900636-01, 01/2017