Fuel Conversion - Jøtul GF 370 DV II IPI Installation And Operation Instruction Manual

Direct vent gas stove
Hide thumbs Also See for GF 370 DV II IPI:
Table of Contents

Advertisement

139647_29 GF 370 DV II IPI 10/23

5. Fuel Conversion

The GF 370 DV II IPI gas stove is shipped from the factory
equipped to burn Natural gas. Propane fuel conversion
kit 156800 is included with the stove to enable use with
LP gas if necessary. The kit contains all the components
needed to complete the task and ensure safe operation,
including labels that must be affixed to the stove.
CAUTION: Before proceeding with this conversion,
the gas supply must be shut off prior to disconnecting
the electrical power.
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, explo-
sion, or production of carbon monoxide may result
causing property damage, personal injury or loss of life.
The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and
complete until the operation of the converted appliance
is checked as specified in the manufacturer's instruc-
tions supplied with the kit.
Cet équipement de conversion sera installé par une
agence qualifiée de service conformément aux instruc-
tions du fabricant et toutes exigences et codes appli-
cables de l'autorisés avoir la juridiction. Si l'information
dans cette Instruction n'est pas suivie exactement, un
feu, explosion ou production de protoxyde de carbone
peut résulter le dommages causer de propriété, pert ou
blessure personnelle de vie. L'agence qualifiée do service
est esponsable de l'installation propre de cet équipe-
metn. L'installation n'est pas propre et complète jusqu'à
l'operation de l'appareil converi est chéque suivant les
critères établis dans les instruction de propriétaire provi-
sion nées avel l'équipement.
Conversion Kit (LP #156800, NG #156801)
Tools required:
• 1/2" & 13 mm open end wrench or deep-well socket
• Torx T20 or slotted screwdriver
• 7/16" open end wrench
• 4 mm allen wrench
Conversion Kit Contents:
• 1 regulator tower labeled for the appropriate fuel
• 2 regulator tower Torx screws
• 1 burner injector (#38 mm for NG, #53 for LP)
• 1, pilot Injector - BL .020 for NG - 226758
.013 for LPG - 226759
• Label A - to be completed and applied to the base of
the valve compartment
16
• 1/4" nut driver
• Label B - apply to the rating plate in the space indi-
cated on the plate.
• Small valve label - apply to valve body
• Conversion instructions
Fuel Conversion Procedure
1. Turn off gas supply to the stove and disconnect from
electrical power source.
2. Remove the glass frame. See fig. 18.
3. Loosen the primary air shutter wingnut and push the
stem all the way back. Fig. 21.
Primary Air
Shutter
Figure 21.
Figure 21. Air Shutter location.
4. Pull the Burner Plate forward to disengage it from the
burner orifice and lift it out of the firebox.
5. Locate the main burner injector. See fig. 23 on page
17. Slide the Air Shutter out of the way and use a 1/2"
open end wrench or deep-well socket to remove the
burner orifice from the brass orifice holder. Replace
with the orifice supplied in the kit. CAUTION: Do
NOT over tighten the Burner Injector. Over tightening
can damage the brass elbow and cause a gas leak!
6. Change the Air Shutter position: Lift the shutter tube
up in its hinge pin slots and turn the tube over, so
that the appropriate fuel type indicator (LP or NG) is
oriented facing you. See fig. 22. Push the shutter all
the way back over the injector.
7. Change the Pilot Injector, Fig. 23 A.
• Use a 1/4" nut driver to remove the sheet metal
screws and Pilot Shield from the pilot assembly.
• Use the 7/16" wrench to remove the pilot head base.
• Remove the pilot injector from pilot base and replace
with the one in the fuel conversion kit.
Figure 22. Primary air shutter orientation must be
changed for fuel type.