Maintenance

This appliance and its venting system should be
inspected before use and at least annually by a
qualified service technician.
WARNING!
THE IGNITION SYSTEM OF THIS APPLIANCE
CARRIES LIVE VOLTAGE. ALWAYS SHUT "OFF "
THE MAIN GAS SUPPLY AND DISCONNECT THE
POWER SOURCE BEFORE PERFORMING ANY
MAINTENANCE PROCEDURE.
TURN "OFF " THE MAIN GAS SUPPLY AND
DISCONNECT THE POWER SUPPLY TO THE
APPLIANCE BEFORE REPLACING BATTERIES

Annual Cleaning

Vent System
The entire vent system should be inspected and
cleaned every year. If the intake and exhaust venting is
disassembled for any reason, it should be reassembled
and sealed according to the vent manufacturer's
instructions provided at the initial installation.
Burner and Log Set
Periodically inspect the firebox and valve
compartment to BE CERTAIN THAT THE FLOW
OF COMBUSTION AND VENTILATION AIR IS
UNOBSTRUCTED. INSPECT THE PILOT ASSEMBLY FOR
CORROSION AND REPLACE ANY AFFECTED PARTS.
The firebox should be vacuumed at least annually
to remove any surface build up. Use a soft brush
attachment and handle the logs carefully as they are
fragile.
Glass Care
Clean the glass as necessary. Wipe the surface with a
clean, dampened, soft cloth. Follow with a dry, soft
towel. Take care not to scratch the glass surface.
WARNING: DO NOT USE ABRASIVE CLEANERS ON
THE GLASS. NEVER CLEAN THE GLASS WHEN IT
IS HOT.
Gasket Inspection
It is important that the glass gasket be inspected at least
annually. Examine the ribbon gasket for signs of dete-
rioration and make sure the gasket has a positive seal.
Replace the gasket if necessary.
NOTE: INSPECT THE GLASS SURFACE FOR
SCRATCHES AS THESE CAN WEAKEN THE PANEL
TENSILE STRENGTH. REPLACE THE PANEL IF ANY
SCRATCHES ARE FOUND. USE ONLY JØTUL CERAMIC
GLASS PANELS: 156835 SIDE AND 156833 FRONT.
Glass Panel or Gasket Replacement
1. Use the 4 mm hex key to remove the four socket screws that
attach the Glass Frame to the firebox.
Remove the lower screws first and be sure to adequately
support the frame against the firebox while you remove the
upper screws.
.
2. Lay the assembly upside down on a flat surface, protecting
the frame from scratches using a blanket or towel.
3. The glass panel is held in place by four retainer tabs. Use a
screwdriver to carefully pry these up off the edge of the glass
retaining walls. If the tabs break off, use the Tinnerman clips
supplied with the replacement glass kit to secure the glass
panel within the frame.
4. Remove the old gasket material.
5. Beginning at the midpoint of the upper edge, apply the new
gasket around the glass panel, with the adhesive side inside
and the thicker portion on the outside. DO NOT STRETCH
THE GASKET MATERIAL. Trim off any excess, leaving a 1/2"
overlap as shown in fig. 58.
6. Lay the glass panel within the glass frame and press the tabs
back down or press the clips in place as shown in fig. 59.
Figure 58.
Gasket application,
PN 129124
StarFire Glass Embers
NOTE: Glass embers may discolor over time, depending upon
frequency of use. Clean the embers by washing in warm, soapy
water, and dry thoroughly before reinstallation and use. After
washing, discard any permanently hazed pieces, or replace
embers annually. Colored glass embers, not supplied by Jøtul,
maybe used, but must be at least 1/2" and similar in size and
shape.
139647_29 GF 370 DV II IPI 10/23