Vertical Venting and Termination
The Jøtul GF 370 DV II IPI can be vertically vented
through a roof or ceiling. Follow these guidelines
Steep roofs, nearby trees, or predominantly windy
conditions, can promote poor draft or down draft
conditions. In such cases, an increase to the height
of the vent may improve performance.
If an offset or elbow is necessary in the vertical rise,
the vent pipe must be supported every three feet to avoid
excessive stress on the offsets. Use listed Wall Straps from
any of the approved vent suppliers.
A maximum of two 90° or four 45° elbows may be
used in a vertical termination. Whenever possible,
use 45° elbows instead of 90° elbows as they offer
less restriction to the flow of flue gases and intake
air.
A listed firestop is required at any floor penetration.
The opening should be framed in according to the
manufacturer's instructions.
Always maintain a minimum 1" clearance from all
sides of the vertical vent system to any combustible
material.
Minimum vertical termination height: 6 ft. of vent
pipe.
139647_29 GF 370 DV II IPI 10/23
Horizontal Overhang
18”.
min.
Termination
Cap
18” min.
IT IS NECESSARY to add restriction to a vertical vent
installation to compensate for excessive draft. See
page 13; Exhaust Restriction Adjustment.
GAS VENT HEIGHT: In no case shall any discharge
opening on the cap be less than 18" (457 mm) hori-
zontally from the roof surface. See fig. 7.
Maximum Vent Height: 35 ft. above the appliance.
18”.
min.
Lowest Discharge
Opening
Figure 7.
Minimum roof penetration height
and clearance from adjacent
surfaces - vertical termination.
9