7. Fuel Conversion

The GF 305 DV IPI gas stove is shipped from the factory
equipped to burn NATURAL GAS only. If PROPANE gas is to
be used as fuel, the appliance must first be converted by
using the Manual Valve Propane Conversion Kit 158024
included with the stove. Use Manual Valve Natural Gas
Conversion Kit 158025 to revert back to
WARNING:
THE CONVERSION KIT IS TO BE INSTALLED BY
AN AUTHORIZED JØTUL SERVICE TECHNICIAN
IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTION AND ALL CODES AND
REQUIREMENTS OF THE AUTHORITY HAVING
JURISDICTION. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN SERIOUS
INJURY OR PROPERTY DAMAGE. THE QUALIFIED
AGENCY PERFORMING THIS WORK ASSUMES
RESPONSIBILITY FOR THIS CONVERSION.
IN CANADA:
THE CONVERSION SHALL BE CARRIED OUT
IN ACCORDANCE WITH THE REQUIREMENTS
OF THE PROVINCIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH THE
REQUIREMENTS OF THE CAN1-B149.1 AND .2
INSTALLATION CODE.
Tools required:
• 1/2" or 13 mm wrench or deep-well socket,
• Torx T20 screw driver
• 1/4" socket driver or spade screwdriver
• 7/16" open-end wrench.
• Small pliers or vice-grip
Conversion Kit Contents:
• 1, regulator tower labeled LP
• LP orifice: 1.55 mm
• Label A - to be completed and applied to
the back of the stove
• Label B - apply to the stove's Rating Plate
NOTE: The Rock Wool supplied with this appliance
may be sprinkled very sparsely on the front of the
burner base to replicate glowing embers. Please be
aware that, under minimum vent configurations,
sooting may occur with Propane fuel. Should soot
develop, use a soft brush to clean the log and
remove some or all of the rock wool from the burner.
Fuel Conversion Procedure
1. Turn off gas supply to stove.
2. Open the door and use the Latch Tool provided to
remove the glass frame and open the firebox. Engage
the Latch Tool with the holes in each spring latch and
pull the latches forward to disengage it from the frame.
natural gas.
Tilt the glass frame forward and lift it out of the stove.
See fig. 2.1, page 5.
3. Open the Controls Compartment Door under the
firebox. Loosen the Air Shutter wing nut and push it
back far as it will travel. See fig. 7.1.
4. Remove the Burner: Grasp the burner base at the two
large air ports and tilt the front up to disengage it
from the firebox. Then tilt it side-to-side and pull it out
through the door opening.
5. Convert the integrated dual-fuel pilot orifice:
• Use the 7/16" wrench to loosen the pilot head base
enough to adjust the orifice conversion shutter. Grasp the
pilot bracket with pliers or vice-grips to prevent it from
bending out of alignment. See fig. 7.2.
LP : push shutter tab to the Right (red LP indicator is
exposed).
NG: push shutter tab Left to hide the red indicator.
• Retighten the pilot base.
OPEN
CLOSED
Figure 7.1. The Air Shutter stem is accessed from within
the controls compartment.
Figure 7.2.
Integrated dual fuel pilot orifice -
LP position shows red dot.
139843_A GF 305 DV IPI 8/17
Front of Stove
P
L
DO NOT BEND
PILOT BRACKET
Air Shutter
Wing Nut
15