139647_29 GF 370 DV II IPI 10/23
Venting Requirements
There are three types of venting configurations
approved for use with this appliance:
• Vertical Venting / Vertical Termination
• Vertical Venting / Horizontal Termination
• Horizontal Venting / Snorkel Termination
This appliance is approved for use with the 4/6
direct vent systems manufactured by the companies
listed on page 8. Use parts of one manufacturer only
- DO NOT MIX VENT COMPONENTS FROM DIFFERENT
MANUFACTURERS WITHIN THE SAME SYSTEM.
Installation of any components not manufactured
or approved by Jøtul or failure to meet all clearance
requirements will void all warranties and could result in
property damage or bodily injury.
The approved vent configurations described
in this manual are derived from extensive testing
under controlled laboratory conditions. Gas
appliance performance can be negatively affected
by variables present in the installation environment,
i.e.; atmospheric pressure, strong prevailing winds,
adjacent structures and trees, snow accumulation, etc.
These conditions should be taken into consideration by
the installer and stove owner when planning the vent
system design.

Approved Vent Manufacturers

The Jøtul GF 370 DV II IPI stove is approved for
installation with direct vent chimney components
supplied by the following manufacturers:
M&G DuraVent, Inc. (Direct Vent Pro Series)
P.O. Box 1510
Vacaville, CA 95696-1510
Selkirk Corporation
1301 W. President George Bush Hwy, Suite 330
Richardson, TX 75080-1139 800-992-8368
American Metal Products (Amerivent)
8601 Hacks Cross Rd.
Olive Branch, MS 38654
Security Chimneys International Limited
2125 Monterey, Laval, Québec
Canada, H7L 3T6
Metal-Fab, Inc. (Sure-Seal Direct Vent)
P.O. Box 1138
Wichita, KS 67201
ICC, Inc.
400 J-F Kennedy St. Jerome, Quebec
Canada, J7Y 4B7
Bernard Dalsin Manufacturing Co. (Pro Form)
5205 208th Street West
Farmington, MN 55024
Olympia Chimney Supply Inc.
600 Sanders Street Suite 2
Scranton, PA 18505-3400
8
800-835-4429
800-423-4270
450-973-9999
316-943-2351
450-565 6336
651- 460-1080
570-496-8890
IMPORTANT
• JOINT SEALING
REQUIREMENT:
APPLY A 1/8" BEAD OF
HIGH-TEMPERATURE
SEALANT OR MIL-PAC®
TO THE MALE SECTION
OF THE INNER VENT
PIPE. THE CEMENT
SHOULD FORM A SEAL
BETWEEN THE INNER
AND OUTER PIPES. DO NOT USE SILICONE. SEE FIG. 6. SEE
VENT MANUFACTURER'S INSTRUCTIONS.
• NEVER MODIFY ANY VENTING COMPONENT, OR USE
ANY DAMAGED VENTING PRODUCT.
• THE GAS APPLIANCE AND VENT SYSTEM MUST
BE VENTED DIRECTLY TO THE OUTSIDE OF THE
BUILDING AND NEVER ATTACHED TO A CHIMNEY
SERVING A SOLID FUEL OR GAS BURNING APPLIANCE.
EACH DIRECT VENT GAS APPLIANCE MUST HAVE
ITS OWN SEPARATE VENT SYSTEM. COMMON VENT
SYSTEMS ARE PROHIBITED.
• IF VENTING SYSTEM IS DISASSEMBLED FOR ANY
REASON, REINSTALL PER THE MANUFACTURER'S
INSTRUCTIONS PROVIDED FOR THE INITIAL
INSTALLATION.