10. The Console display shows the System Units prompt
with the current setting. Tap the Programs button 4 times to
advance through the System Menu.
11. The Console display shows the Hardware Variant &
Console Firmware Version. The sample screen shows the
format (values may be different).
Push and hold for 3 seconds the Resistance Level Quick 25
button to go to the Manufacturing Test Menu.
12. The Console display shows the START TEST SUITE
menu option. Push the Resistance Down () button 2 times
to advance to the AUTO CAL_RESISTANCE (Automated
Calibrate Resistance) option.
If the Start button was pushed instead of the Resistance
Down () button twice, turn the Power Switch to OFF and
return to Step 1.
When the display shows "CALIBRATE RESISTANCE" do
NOT push Start. This option is not used. Push the Resistance
Down () button one more time.
If the Resistance Down () button was pushed more than 2
times going past the AUTO CAL_RESISTANCE option, push
the Resistance Increase () button to return to the AUTO
CAL_RESISTANCE (Automated Calibrate Resistance)
option.
13. The Console display shows the AUTO CAL_RESIS-
TANCE (Automated Calibrate Resistance) option. Push the
Start button.
Note: If the Pause/Stop button is pushed part way
through the calibration (exit), the new calibration is
not saved.
14. The console will display changing text and numbers for
approximately 30 seconds as the servo motor moves.
55