Schwinn 490e Service Manual page 20

Elliptical
Table of Contents

Advertisement

Do not use the Console Resistance Quick Keys to set resistance until the calibration
!
process is complete and calibration saved.
Note: During the calibration process no one should be pedaling the machine. Standing on the pedals is okay during the
calibration process.
1.
Plug the power cord into the machine and wall outlet,
and flip the power switch to on.
2. Push the Programs button and hold for 3 seconds while
in the Power-Up Mode to go into the Console Setup Mode
(System Menu).
Note: T o exit the System Menu and return to the Power-
Up Mode screen, push the Pause/Stop button.
3. The Console display shows the System Units prompt
with the current setting. Tap the Programs button 4 times to
advance through the System Menu.
4. The Console display shows the Hardware Variant &
Console Firmware Version. The sample screen shows the
format (values may be different).
Push and hold for 3 seconds the Resistance Level Quick 25
button to go to the Manufacturing Test Menu.
5. The Console display shows the START TEST SUITE
menu option. Push the Resistance Down () button 2 times
to advance to the AUTO CAL_RESISTANCE (Automated
Calibrate Resistance) option.
If the Start button was pushed instead of the Resistance
Down () button twice, turn the Power Switch to OFF and
return to Step 1.
When the display shows "CALIBRATE RESISTANCE" do
NOT push Start. This option is not used. Push the Resistance
Down () button one more time.
If the Resistance Down () button was pushed more than 2
times going past the AUTO CAL_RESISTANCE option, push
the Resistance Increase () button to return to the AUTO
CAL_RESISTANCE (Automated Calibrate Resistance)
option.
Resistance Level Quick 25 button
Resistance Down button
20