2. Remove the cable that is being replaced (Offline Power
Supply to Sensor Hub (DC Power) Cable, or Lift Motor
Control Cable) from the Sensor Hub and the Offline Power
Supply.
Note: Be sure to note where all cables attach for
re-assembly. Do not let the cables fall into the
machine. If the Cable Connectors are secured by
a small amount of glue, use a pair of small nose
pliers to grab and remove the glue.
NOTICE: Do not cut or pinch the cables.
3. Connect the new cable to the Sensor Hub and the
Offline Power Supply.
NOTICE: Do not cut or pinch the cables.
Sensor Hub
Offline Power
Supply to Sensor
Hub (DC Power)
Cable
26
Lift Motor Con-
trol Cable
Offline Power
Supply