Minolta EP1030 Manual page 35

Hide thumbs Also See for EP1030:
Table of Contents

Advertisement

6.
Press the Start Key to and use the Copy Quantity and Zoom Keys to change the settings for the Lead-
ing Edge Erase Width Adjustment.
7.
Press the Clear/Stop Key to set the settings.
Setting Instructions
@ If dimention A on the copy is longer than 4.0 mm, increase the setting value.
@ If dimention A on the copy is Shorter than 3.0 mm, decrease the setting value.
* If the measurement does not fall within the specifications through one setting, try another setting.
Touch This Key If
Measurement is Longer.
Touch This Key
if
1159D024AA
Measurement Is Shorter.
8.
After the adjustments have been made, press the Clear/Stop Key to restore the copier to the normal
copy mode.
D-62
(12) Adjustment of Edge Erase (EP1031/EP1031F only)
@ Requirement
@ Ready atest chart as shown on the left. Adjust so thatthe
difference between widths A and B in the illustration on
the left falls within the following specifications on the
copy made at x 0.64.
© Specification ....... B Width -A Width = + 1.0mm
NOTE
1150D149AA
| Width A plus B must be 120 mm or more.
@ Important
® This adjustment should be made after the "adjustment of reference options".
:
on
Nowe'
1.
Place the Test Chart on the reference position for the Origi-
nat Width Scale and close the Original Cover.
2.
Make a one copy using Ad or 8-1/2" x 14" paper at a re-
duction ratio of x 0.64.
3.
Ifthe specifications are not met, adjust by moving the Edge
Erase Lamp in the direction of the arrow.