T169SBS050404A
4. Test
© This function allows the Tech. Rep. to perform various functional test and adjustment.
<Setting Procedure>
1. Select the Test function. ("F1" appears on the Display Panel.)
,
2. Select the subfunction to be adjusted or checked using the Copy Quantity and Zoom Key @ and
press the Start Key.
<Leaving the Function>
® Select the next Test subfunction using the Copy Quantity and Zoom Key © or press the Clear/Stop
Key to quit the Test function.
[Service Mode > Test]
<Paper Passage Test> .
This test moves the paper through the copier for correct passage.
<Procedure>
1. Press the Start Key to start the sequence.
2. Press the Clear/Stop Key to stop the sequence.
<Corona output>
Do not use this test as it is only for factory adjustment.
<Exposure Lamp Voltage Adjustment>
This test allows the Tach. Rep. to adjust the maximum Exposure Lamp
voltage and the optimum exposure setting in the Manual Exposure mode. (It
runs for 30 sec.)
NOTE
For details, see DIS/REASSEMBLY, ADJUSTMENT.
|
<AE Sensor Automatic Adjustment>
This test automatically adjusts the AE sensor. (It runs for 5 sec.)
NOTE
| For details, see DIS/REASSEMBLY, ADJUSTMENT.
|
<ATDC Sensor Automatic Adjustment>
This test automatically adjusts the ATDC sensor.
S-16
e
Test Operation
Component
Main Drive Motor
PC Drum Charge
Edge Erase Lamp
[Service Mode > Test]
~ Components Energized in the Test —
S-17
©: Energized
— : Remain deenergized