Press the Start Key and use the Copy and Zoom Keys to change the settings
for the Enlargement Reg-
istration.
6.
Press the Clear/Stop Key to set the settings.
Setting Instructions
®@ If dimention A on the copy is longer than 33.6 mm, increase the setting value.
@ If dimention A on the copy is Shorter than 28.8 mm, decrease the setting value.
* If the measurement does not fall within the specifications through one setting, try another setting.
Touch This Key If
Measurement is Longer.
Touch This Key
if
1159D024AA
rement [s Shorter.
7.
After the adjustments have been made, press the Clear/Stop Key to restore the copier to the normal
copy mode.
D-58
(10)-3. Leading Edge Registration In Reduction Mode
Once the Enlargement Registration has been adjusted,
make one copy using A4 or 8-1/2" x 14" paper ata x
0.64 reduction ratio.
If the registration is up to the specifications, go to the ad-
justmentin the reduction mode. Ifitdeviates from the spec-
ifications, perform the following steps to make the adjust-
ment of leading edge registration In the enlargement
made.
® This adjustment should be made after the "adjustment of leading edge registration in the full size
_ mode".
3.
Set to Service Mode.
4.
To adjust the A5 Reduction Registration, press the following keys in the indicated sequence: Copy
Quantity and Zoom Key @ two times; the Start Key one time and the Copy Quantity and Zoom Key
© five times.
Press the Keys in order of [1], [2]. [3],
[4], {5). [6], [7], and [8].
"AS" will appear in the Display Panel.
D-59